Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

16 June 2004

Diagnostic imaging of carcinoid metastases to the abdomen and pelvis

Jarosław B Ćwikła, John R Buscombe, Martyn E Caplin, Anthony F Watkinson, Jerzy Walecki, Ewa Gorczyca-Wiśniewska, Andrew J W Hilson

Med Sci Monit 2004; 10(3): 9-16 :: ID: 11866

Abstract

Background:Functional and anatomical imaging methods are currently the standard approach to the evaluation of carcinoid tumor extent. Due to the nature of carcinoid tumors ,there is not a single imaging procedure that is sufficient to detect the malignancy. The aim of the study was to compare the value of CT, MR and functional imaging study with[sup]111[/sup] In-Octreotide (SRS) in carcinoid detection and evaluation of its extent as well as to work out the imaging studies diagnostic algorithm that could enhance diagnostic efficacy.Material/Methods: A total of 34 patients with carcinoid tumor confirmed clinically,biochemically and/or histopathologically were enrolled into the study. Computed tomography (CT) examinations of the abdomen and pelvis were performed before and after administration of a contrast medium, the triple-phase liver scanning included .Magnetic Resonance Imaging (MRI)of the liver was performed according to the standardized protocol before and after administration of a contrast medium .Planar scintigraphy with[sup]111[/sup] In Octreotide and SPECT were performed. In each case liver as well as lymph node metastases in the abdomen and pelvis weresearched for. All results were reviewed independently. Clinical picture at follow-up and further imaging and/or histological studies confirmed or excluded the diagnosis of the disease.Results: Twenty nine patients were diagnosed with carcinoid tumor. Liver metastases were found in 26 patients and lymph node metastases were detected in 18 of them. Complete diagnostic conformity as far as the diagnosis and extent of the disease are concerned was obtained only in 7 cases. Incorrect assessment of the disease extent was the source of discrepancy between the imaging studies results in most of the remaining 22 patients. The SRS and MR results of liver metastases detection were mostly consistent with one another. Both imaging modalities evaluated the extent of hepatic metastases incorrectly in 22%of the patients,as compared to 43% of the patients for CT. The highest proportion percentages of incorrect results of lymphatic involvement detection were 41%, 29%and 43%for MR, SRS and CT, respectively.Conclusions: The results of our study have indicated that application of a complex imaging algorithm enables higher accuracy of hepatic and lymph nodes metastases detection in carcinoid tumor patients. Combining the results of MR and SRS in evaluating the extent of the carcinoid disease seems to represent higher diagnostic value than relying on one of this method in combination with CT images.

Keywords: carotid and cerebral arteries, CTABACKGROUNDe-mail:[email protected] and cerebral arteries, CTA, atherosclerosis

Add Comment 0 Comments

Editorial

01 December 2024 : Editorial  

Editorial: The 2024 Revision of the Declaration of Helsinki and its Continued Role as a Code of Ethics to Guide Medical Research

Dinah V. Parums

DOI: 10.12659/MSM.947428

Med Sci Monit 2024; 30:e947428

0:00

In Press

Clinical Research  

Machine Learning Models for Predicting 24-Hour Intraocular Pressure Changes: A Comparative Study

Med Sci Monit In Press; DOI: 10.12659/MSM.945483  

Clinical Research  

Cost Reduction in Blood Transfusions After Implementation of Decision Protocol Based on Hemoglobin and Anem...

Med Sci Monit In Press; DOI: 10.12659/MSM.945854  

Clinical Research  

Impact of Comprehensive Preoperative Assessments on Gynecological Ambulatory Surgery Outcomes in a Chinese ...

Med Sci Monit In Press; DOI: 10.12659/MSM.945771  

Animal Research  

Histological Evaluation of the Effects of Intra-Articular Injection of Caffeic Acid on Cartilage Repair in ...

Med Sci Monit In Press; DOI: 10.12659/MSM.946845  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,956,165

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research   1,947,492

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   696,690

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

07 Jan 2022 : Meta-Analysis   262,693

Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...

DOI :10.12659/MSM.935074

Med Sci Monit 2022; 28:e935074

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750