Abstract
Background: Children with hydropcephalus and increased intracranial pressure are treated with ventricular shunts. Multiple head CT is used to assess shunt malfunction and changes in ventricular size (volume). Because of the naturally high contrast of the head structures in CT imaging, a low-dose protocol for hydrocephalic pediatric patients was proposed. The aim of the study was to assess the implemented protocol in categories of radiation risk to the patients.
Material and Methods: Head CT examinations were performed using the fourth-generation single-slice scanner PQ-2000 (Picker). Exposure parameters of the routine head procedure stored in the scanner software were the starting point for the investigation. The acceptable ranges of the modified parameters were found on the basis of earlier published results. The effect of the new protocol on image quality was tested using a CATPHAN phantom. The organ doses were evaluated experimentally. The clinical images were evaluated by two experienced and independent radiologists. Results: Head CT examinations were performed in 380 children with hydrocephalus during a 10-year period at the Department of Diagnostic Imaging Polish Mother’s Memorial Hospital. Until 2005 these children were examined according to the routine protocol of the scanner, i.e. 10 mm contiguous axial, 120 kVp, and 225 mAs. Then the protocol was modified to 10 mm contiguous axial, 100 kVp, and 150 mAs. Reductions in patient doses to 70% were found while the clinical images maintained sufficient diagnostic value. Conclusions: The low-dose protocol for head CT can be recommended for the monitoring of pediatric hydrocephalus patients.
Keywords: Adolescent, Child, Child, Preschool, Head - radiography, Hydrocephalus - therapy, Infant, Newborn, Intracranial Hypertension - radiography, Radiation Dosage, Tomography, X-Ray Computed - methods, Ventriculoperitoneal Shunt
Editorial
01 September 2024 : Editorial
Editorial: Reasons for Increasing Global Concerns for the Spread of MpoxDOI: 10.12659/MSM.946343
Med Sci Monit 2024; 30:e946343
In Press
Clinical Research
Intravenous Lidocaine Response as a Predictor for Oral Oxcarbazepine Efficacy in Neuropathic Pain Syndrome:...Med Sci Monit In Press; DOI: 10.12659/MSM.945612
Review article
Cariprazine in Psychiatry: A Comprehensive Review of Efficacy, Safety, and Therapeutic PotentialMed Sci Monit In Press; DOI: 10.12659/MSM.945411
Clinical Research
Comparison of Remimazolam and Dexmedetomidine for Sedation in Awake Endotracheal Intubation in Scoliosis Su...Med Sci Monit In Press; DOI: 10.12659/MSM.944632
Database Analysis
Knowledge, Awareness, and Use of Stainless-Steel Crowns Among Dental Professionals in Sana'a City, YemenMed Sci Monit In Press; DOI: 10.12659/MSM.945948
Most Viewed Current Articles
17 Jan 2024 : Review article 6,053,504
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research 1,840,784
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 693,030
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
07 Jan 2022 : Meta-Analysis 257,470
Efficacy and Safety of Light Therapy as a Home Treatment for Motor and Non-Motor Symptoms of Parkinson Dise...DOI :10.12659/MSM.935074
Med Sci Monit 2022; 28:e935074