Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

02 July 2022: Clinical Research  

A Simulation Study Using a Quality Cardiopulmonary Resuscitation Medical Manikin to Evaluate the Effects of Using Personal Protective Equipment on Performance of Emergency Resuscitation by Medical Students from the University of Silesia, Katowice, Poland and Non-Medical Personnel

Michał Starosolski1ABE*, Beata Zysiak-Christ2AB, Alicja Kalemba3ABCDEF, Cezary Kapłan3ABCDEF, Krzysztof Ulbrich ORCID logo3BE

DOI: 10.12659/MSM.936844

Med Sci Monit 2022; 28:e936844

0 Comments

Abstract

BACKGROUND: During the Coronavirus disease 2019 (COVID-19) pandemic, personal protective equipment (PPE) is used during medical resuscitation aerosol-generating procedures (AGP). This simulation study aimed to evaluate the effects of PPE on the performance of emergency resuscitation by medical students from the University of Silesia, Katowice, Poland and non-medical personnel, and used a quality cardiopulmonary resuscitation (Q-CPR) medical manikin.

MATERIAL AND METHODS: A simulation study was conducted using the Resusci Anne quality cardiopulmonary resuscitation (Q-CPR) medical manikin (Laerdal Medical AS, Norway). Participants were divided into 2 groups: a medical group of 50 and a non-medical group of 52, matched in pairs. Each pair performed 10 min of manual CPR with a compression-ventilation ratio of 30: 2 wearing PPE for AGP. The reference method was manual CPR wearing casual clothes along with surgical masks and latex gloves. Data about compression and ventilation were gathered using the QCPR Training application from Laerdal Medical.

RESULTS: Data analyses indicated statistically significant differences between medical students using PPE for AGP and basic protection: average rate of chest compressions (123 vs 114 per min; P=0.004), chest recoil (69 vs 93; P=0.0050, correct depth of chest compressions (86.5 vs 97; P=0.0081), quality of ventilation (85 vs 89; P=0.0041). Among non-medical personnel however, a statistically significant difference was in the quality of ventilation (69-85.5; P=0.0032).

CONCLUSIONS: The findings from this study showed that the use of PPE for AGP during CPR was associated with slower average speed of chest compressions, less chest recoil, incorrect depth of chest compressions, and lower quality of ventilation.

Keywords: Cardiopulmonary Resuscitation, Emergency Medicine, SARS-CoV-2, Simulation Training, COVID-19, Humans, Manikins, personal protective equipment, Poland, Students, Medical

Background

Cardiopulmonary resuscitation (CPR) is regarded as one of the medical procedures that generate aerosols [1]. The novel pathogen, severe acute respiratory syndrome Coronavirus type 2 (SARS-CoV-2), causing the global Coronavirus disease 2019 (COVID-2019) pandemic is to our misfortune transmitted by aerosols defined as droplets <5 μm in diameter [2]. This foregoing feature generates not only the possibility of infection during CPR, but also contributes to changes in its procedure. Emergency workers are at high risk of SARS-CoV-2 infection, which can lead to severe and life-threatening complications [3]. The chances of transmission of infection are relatively high [4]. One study showed that as many as 20% of patients in out-of-hospital cardiac arrest during the start of the pandemic in Europe were infected with SARS-CoV-2 [5]. The European Resuscitation Council (ERC) in its resuscitation guidelines adapted for COVID-19 notes deployment of personal protective equipment (PPE) as an airborne-precaution [6]. Other organizations, such as the International Liaison Committee on Resuscitation (ILCOR), American Heart Association (AHA), and UK Resuscitation Council, have published generally consistent guidelines [7]. The ERC recommends wearing PPE before CPR, consisting of at least a filtering facepiece 3 (FFP3) mask (if FFP3 is not available, then FFP2 or N95), gloves, eye and face protection, and a long-sleeved gown [6]. Concerns about the deterioration of quality of CPR arise when we consider data indicating impairment of medical procedures due to the use of PPE [8,9]. Those associated with medical education (ie, medical students, physicians, nurses, paramedics) are not the only people responsible for administering CPR, but there are others, especially those involved in rescue operations (ie, soldiers, firefighters, water and mountain rescuers).

Therefore, this simulation study aimed to evaluate the effects of PPE on the performance of emergency resuscitation by medical students from the University of Silesia, Katowice, Poland and non-medical personnel.

Material and Methods

This prospective simulation study did not require bioethics committee approval because it was performed on mannequins. All participants voluntarily consented to participate in the study. There were no gratuities for participation in the study. The study was conducted from March to June 2021. Due to standardization of their knowledge, participants were divided into 2 groups: 25 pairs of medical students and 26 pairs of non-medical personnel. The study group consisted of: 50 medical students (32 5th-year students and 18 6th-year students from the Medical University of Silesia in Katowice and 52 non-medical personnel from Silesia and Lower Silesia districts, including Generał Tadeusz Kościuszko Military University of Land Forces in Wrocław students (14), volunteer firefighters (14), and volunteer water rescuers (24).

Non-medical professionals are obligatorily trained in first aid. The training program is regulated by the Minister of Health [10]. The training lasts 66 h, during which participants learn high-quality CPR and ventilation with BMV (bag-mask-ventilation devices). Students of medical universities must acquire the skills related to conducting high-quality CPR and proper ventilation of the patient using bag-mask-ventilation devices. The training program for students of the medical faculty is regulated by the Regulation of the Minister of Science and Higher Education [11].

The study used simple randomization. The Research Randomizer program was used for this purpose. Medical and non-medical participants within their groups were randomly assigned to pairs. Within each pair, the type of protection (PPE for AGP/basic protection) used in first attempt and the participants’ role (chest compression/ventilation) in the first cycle of CPR were randomized (Figure 1).

The study investigated how effectively participants performed cardiac compressions with and without PPE for AGP. Accordingly, participants were asked to perform 2 resuscitation attempts. One required the use of PPE for AGP while the other required basic personal protection.

PPE for AGP included double nitrile gloves (Light Nitrile Powder-Free Examination Gloves, Sri Trang Gloves Public Company Limited, Bangkok, Thailand), mask Air-purifying Respirator (APR) high protection level (Panoramamasque EPDM/PMMA with filter, Honeywell, Charlotte, United States), eye protection goggles (Uvex Goggles, Honeywell, Charlotte, United States), and biological protection suit type 5 and 6 antistatic PROTEX 4000 (Irudek, Poland).

Basic personal protection consisted of casual outfits along with nitrile gloves (Light Nitrile Powder-Free Examination Gloves, Sri Trang Gloves Public Company Limited, Bangkok, Thailand) and N95 masks (Med Mask, Poland).

Before starting the trial, each participant was trained on how to correctly wear PPE for AGP. During each trial, participants were supervised by researchers to ensure that the participants properly wore PPE and to supervise them during the trial.

Consecutively, each pair performed 10-min manual CPR (ventilation was performed using a bag-mask ventilation device) in each form of protection. Resuscitation was performed according to the guidelines of the European Resuscitation Council 2021 [12]. The person performing compressions was changed every 2 min. The interval between each attempt was 20 min and was followed by a second attempt of CPR in a different form of protection. The simulation was performed using a Resusci Anne quality cardiopulmonary resuscitation (Q-CPR) medical manikin (Laerdal Medical AS, Norway).

Data about compression and ventilation quality were gathered from the QCPR Training application manufactured by Laerdal Medical AS, Norway.

The inclusion criteria for participants included: no COVID-19 symptoms in the last 14 days, no quarantine, and a negative test for SARS-CoV-2 in the last 14 days.

The database was collected in Microsoft 365 Excel, Microsoft Corporation, and statistical analyses were performed using MedCalc for Windows version 19.4 (MedCalc Software, Ostend, Belgium). Differences between quantitative variables were assessed using the t test (for paired variables) or the Wilcoxon test, depending on the character of distribution. Correlations were assessed by Pearson’s linear correlation coefficient or Spearman’s rank test.

A correlation was revealed among the group of medical students wearing PPE for AGP between chest compression fraction (CCF) and compression quality (CQ) (R=0.544; P=0.005). According to the QCPR application, appropriate compression is indicated when the depth of compression is at least 50 mm. The percentage that meets the above criteria has been calculated in the total chest compressions. There was also a correlation between CQ and the average speed of compression (avg.soc) in the medical students’ group wearing basic protection (R=0.809; P<0.0001). Moreover, in the non-medical personnel group with PPE for AGP, there was a statistically significant correlation between CQ and avg.soc (R=0.907; P<0.0001). Among the personnel in basic protection, CQ and avg.soc were correlated (R=0.872; P<0.0001) (Figures 2–5).

Discussion

This study showed the impact of using PPE for AGP on quality of CPR among medical students. According to the results, most of the determinants of CPR, including average speed of chest compressions, chest recoil, correct depth of chest compressions, and quality of ventilation, had deteriorated.

Resuscitation among non-medical personnel showed no significant differences during CPR between PPE for AGP and basic personal protection attempts. For non-medical personnel, the fact of performing CPR in PPE for AGP does not significantly differ in the quality of the medical procedures, which may indicate a lower initial level of CPR skills. Unfortunately, 2 independent studies by Baldi and Willmore showed that the level of knowledge of medical students is not sufficient [13,14].

Therefore, both medical and non-medical personnel require regular improvement of CPR skills in PPE for AGP with the use of feedback devices along with full debriefing of the results achieved. Regular training can provide medical and non-medical personnel with adequate skills to perform high-quality CPR in case of highly transmissible diseases in the future. This is all the more important to consider in view of the results of the Saad’s study, where it was observed that the retention of skills in medical students remains at 61% 42 months after 10 h of training in basic life support [15].

The epidemiological situation forces both groups (medical personnel and non-medical personnel) to perform CPR using personal protective equipment (PPE for AGP). Suhe Serin et al compared the effect of different personal protective equipment masks on health care workers, finding that use of protective masks other than surgical as PPE increased rescuer fatigue in CPR and negatively affected the quality of chest compressions. Our study showed that in the medical personnel group, the use of surgical masks was associated with better quality of CPR, which agrees with Suhe Serin’s research. Some studies explicitly say that performing CPR without PPE for AGP is associated with an increase of cardiac compression quality [16], but in our opinion, performing CPR without PPE for AGP is associated with a significant risk of infection of medical personnel and should not be used. Performing CPR in the ALS algorithm includes, apart from chest compression and ventilation, other procedures, such as intravenous cannulation (IVC) and instrumental securing the airway, for example using endotracheal intubation (ETI) or using supraglottic devices. The above procedures are known to be 3 key life-saving interventions that should be performed immediately to save the patient’s life. The study conducted by Tae Han Kim et al revealed that using PPE for AGP is associated with a decrease not only in the chest compression quality but also the success rate of IVC and ETI [17].

It was not our intention to check the level of fatigue during cardiopulmonary resuscitation, but the participants of the study raised the aspect of physical exhaustion after the simulation in a biological protection suit. Our observations are supported by Rauch et al, in which the participants also subjectively felt more exhausted [18]. In addition, fatigue has been shown to have a physiological basis in the form of increased heart rate and mean arterial pressure [19]. Interestingly, Badaki-Makun et al suggested that peak power output during the performance of CCs is comparable to that generated during intense exercise such as running (154 W for a 70-kg man running on a level surface at 9 km/h) or swimming (158 W for a 70-kg man swimming at high intensity in a pool) [20,21]. Our study found the least decrease in the quality of chest compressions in students of the Land Forces Academies. This is most likely due to the significantly greater amount of time devoted to adequate training and maintaining good physical performance in this group of people.

In our study, we also demonstrated a statistically significant difference in resuscitation effectiveness in PPE compared to no PPE in the medical group. This observation is consistent with meta-analyses conducted by Sahu et al [4] and in the Randomized Crossover Simulation Study conducted by Chen et al [19]. In contrast, the non-medical group showed no difference in efficacy with or without PPE. This conclusion is consistent with the study by Donoghue et al [22], but there are significant differences between these studies. In the study cited above, chest compression was the only activity performed by the participants and was performed continuously for 5 min. Moreover, the manikin on which the tests were conducted was a pediatric manikin, in contrast to the adult simulator used by us. Only medical personnel were tested, whereas our group included of non-medical personnel with training.

When considering resuscitation procedures among people with suspected or confirmed infection with SARS-CoV-2 or any other infectious disease, the primary consideration should be the safety of rescuers. However, we should also focus on maintaining adequate quality of CPR. We agree with the suggestions of Malysz et al, which emphasizes the need to adapt resuscitation algorithms to the situation when PPE is required [23].

Certainly, regular shifts of those performing the most exhausting activities should be implemented and perhaps consideration should be given to reducing the length of the chest compression cycle. The situations where CPR providers are exhausted and no longer have the strength to continue may be dangerous for patients and themselves. Cekmen’s study showed that changing the rescuer every 1 min instead of every 2 min during full PPE resuscitation can prevent the reduction in compression quality that can occur as resuscitation time increases [24]. Therefore, the use of automatic chest compression devices should be considered. There is no doubt that further research comparing the effectiveness of resuscitation using PPE is needed, including comparing the quality of resuscitation by people using PPE versus the use of automated chest compression devices.

A limitation of this study is its simulation structure. In a non-simulation setting, the stress of a life-threatening situation plays a major role. The mannequin does not mimic human anatomy or size, which is another limitation of our work. Moreover, participants had unlimited time to put on personal protective equipment, which certainly in real life would be shorter and could determine the quality of protection. Another limitation of our work is the lack of a survey to allow participants to evaluate the influence of the protection on their fatigue. Another limitation is that participants had to perform only CPR; activities related to securing the airway or administering medications were omitted.

Conclusions

The findings from this study showed that the use of PPE for AGP during CPR was associated with lower average speed of chest compressions, less chest recoil, less correct depth of chest compressions, and lower quality of ventilation.

References

1. World Health Organization: Transmission of SARS-CoV-2: Implications for infection prevention precautions: scientific brief July 09, 2020, World Health Organization

2. Van Doremalen N, Bushmaker T, Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1: N Engl J Med, 2020; 382; 1564-67

3. Badraoui R, Alrashedi M, El-May M, Acute respiratory distress syndrome: A life threatening associated complication of SARS-CoV-2 infection inducing COVID-19: J Biomol Struct Dyn, 2021; 39(17); 6842-51

4. Sahu AK, Suresh S, Mathew R, Impact of personal protective equipment on the effectiveness of chest compression – a systematic review and meta-analysis: Am J Emerg Med, 2021; 39; 190-96

5. Sultanian P, Lundgren P, Strömsöe A, Cardiac arrest in COVID-19: Characteristics and outcomes of in- and out-of-hospital cardiac arrest. A report from the Swedish registry for cardiopulmonary resuscitation: Eur Heart J, 2021; 42; 1094-106

6. Nolan JP, Monsieurs KG, Bossaert L, European Resuscitation Council COVID-19 guidelines executive summary: Resuscitation, 2020; 153; 45-55

7. Kundra P, Vinayagam S, COVID-19 cardiopulmonary resuscitation: Guidelines and modifications: J Anaesth Clin Pharm, 2020; 36(Suppl 1); 39-44

8. Wiechmann W, Toohey S, Majestic C, Intubating Ebola patients: Technical limitations of extensive personal protective equipment: West J Emerg Med, 2015; 16; 965

9. Martín Rodríguez F, Fernández Pérez C, Castro Villamor MDoes level D personal protective equipment guard against hazardous biologic agents during cardiopulmonary resuscitation?: Emergencias, 2018; 30; 119-22 [in Spanish]

10. : Obwieszczenie Ministra Zdrowia z dnia 24 lutego 2021 r. w sprawie ogłoszenia jednolitego tekstu rozporządzenia Ministra Zdrowia w sprawie kursu w zakresie kwalifikowanej pierwszej pomocy. Dz.U, 2021; 411 Available from: [in Polish]http//isap.sejm.gov.pl/isap.nsf/DocDetails.xsp?id=WDU20210000411&SessionID=2CF8B70A08878E6C5BBC998ED5A879497C5E7796

11. : Rozporządzenie Ministra Nauki i Szkolnictwa Wyższego z dnia 26 lipca 2019 r. w sprawie standardów kształcenia przygotowującego do wykonywania zawodu lekarza, lekarza dentysty, farmaceuty pielęgniarki położnej diagnosty laboratoryjnego, fizjoterapeuty i ratownika medycznego Dz. U2019 poz. 1573 Available from [in Polish]https://isap.sejm.gov.pl/isap.nsf/DocDetails.xsp?id=WDU20190001573

12. Olasveengen TM, Semeraro F, Ristagno G, European Resuscitation Council Guidelines 2021: Basic life support: Resuscitation, 2021; 161; 98-114

13. Baldi E, Contri E, Bailoni A, Final-year medical students’ knowledge of cardiac arrest and CPR: We must do more!: Int J Cardiol, 2019; 296; 76-80

14. Willmore RD, Do medical students studying in the United Kingdom have an adequate factual knowledge of basic life support?: World J Emerg Med, 2019; 10(2); 75-80

15. Saad R, Sampaio Favarato MH, Ferreira de Paiva E, Medical student skill retention after cardiopulmonary resuscitation training: A cross-sectional simulation study: Simul Healthc, 2019; 14(6); 351-58

16. Hacımustafaoğlu M, Çağlar A, Öztürk B, The effect of personal protective equipment on cardiac compression quality: Afr J Emerg Med, 2021; 11; 385-89

17. Kim TH, Kim CH, Shin SD, Haam S, Influence of personal protective equipment on the performance of life-saving interventions by emergency medical service personnel: Simulation, 2016; 92; 893-98

18. Rauch S, van Veelen MJ, Oberhammer R, Effect of wearing personal protective equipment (PPE) on cpr quality in times of the COVID-19 pandemic – a simulation, randomised crossover trial: J Clin Med, 2021; 10; 1728

19. Chen J, Lu KZ, Yi B, Chen Y, Chest compression with personal protective equipment during cardiopulmonary resuscitation: A randomized crossover simulation study: Medicine (Baltimore), 2016; 95; 3262

20. Badaki-Makun O, Nadel F, Donoghue A, Chest compression quality over time in pediatric resuscitations: Pediatrics, 2013; 131; 797-804

21. Jetté M, Sidney K, Blümchen G, Metabolic equivalents (METS) in exercise testing, exercise prescription, and evaluation of functional capacity: Clin Cardiol, 1990; 13; 555-65

22. Donoghue AJ, Kou M, Good GL, Impact of personal protective equipment on pediatric cardiopulmonary resuscitation performance: A controlled trial: Pediatr Emerg Care, 2020; 36; 267-73

23. Malysz M, Dabrowski M, Böttiger BW, Resuscitation of the patient with suspected/confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial: Cardiol J, 2020; 27; 497-506

24. Cekmen B, Bildik B, Bozan O, Chest compression quality during CPR of potential contagious patients wearing personal protection equipment: Am J Emerg Med, 2022; 52; 128-31

In Press

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

26 Feb 2024 : Clinical Research  

Predictive Value of Combined HbA1c and Neutrophil-to-Lymphocyte Ratio for Diabetic Peripheral Neuropathy in...

Med Sci Monit In Press; DOI: 10.12659/MSM.942509  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750